Documents

Useful Documents to Download

Product Feature Overview

This document outlines the main features and advantages of the Kingspan TEK® Building System.

Download Document

CodeMark Certification

KnightBuilt's installation process and the Kingspan TEK® Panel Building System have CodeMark certification for New Zealand - meaning building consent attainment for this product is assured.

Download Document

142mm Construction Manual

Outlines the process we follow for constructing the outer building shell using the Kingspan TEK® Panel Building System 142mm thickness.

Download Document

142mm Construction Manual Addendum

This document is supplied as an addendum to the 142mm Construction Manual and describes acceptable variations and practices for the NZ market in order to be compliant with the Codemark certification.

Download Document

172mm Construction Manual

Outlines the process we follow for constructing the outer building shell using the Kingspan TEK® Panel Building System of 172mm thickness.

Download Document

172mm Construction Manual Addendum

This document is supplied as an addendum to the 172mm Construction Manual and describes acceptable variations and practices for the NZ market in order to be compliant with the Codemark certification.

Download Document

Standard Connection Details - 142mm

Examples of design drawings for typical wall-to-floor, roof-to-wall, corner connections, etc. for the 142mm panel.

Download Document

Standard Connection Details - 172mm

Examples of design drawings for typical wall-to-floor, roof-to-wall, corner connections, etc. for the 172mm panel

Download Document

Screw Pull-Out Capacities

Details screw pull-out capacities from the Kingspan TEK® Panel when considering cladding loads.

Download Document

Roof Span Overview

Outlines Kingspan TEK® Panel spanning capacities for roofing applications

Download Document

Roof Span NZ Calcs

The attached document contains roof span tables for both 142mm and 172mm deep panels for NZ building regulations.

They can be used in replacement of Table 10.1 of NZS3604 and we have also included tables for when 1.5kPa or 2.0kPa ground snow loads are applied.

For additional refinement we have allowed for up to 6 different roof slope angle options. Please note that roof spans are to be measured horizontally, not along the roof slope. This allows direct comparison on a roof framing plan.

Download Document

P21-Tests and Bracing Calculations

Please contact us at info@knightbuilt.co.nz for these details and any other technical details you might require.

Certified Passive House Component

This document shows certification of the Kingspan TEK® Building System as a "Certified Passive House Component" by the Passive House Institute.

Download Document